Casa ProdutosInstrumento de Teste Elétrico

Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

    • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
    • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
    • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
    • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
    • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter
  • Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

    Detalhes do produto:

    Lugar de origem: CHINA
    Marca: AI
    Certificação: ISO
    Número do modelo: Dft

    Condições de Pagamento e Envio:

    Quantidade de ordem mínima: 1 conjunto
    Preço: Negociável
    Detalhes da embalagem: Caixa
    Tempo de entrega: 15 dias
    Termos de pagamento: T/T, Western Union, L/C
    Habilidade da fonte: 100000 conjuntos por mês
    contacto
    Descrição de produto detalhada
    Fonte de energia: CA 220V±10% Mostrar: LCD
    palavra-chave: Testador de fator de dissipação, medidor de resistividade de volume Saída CA HV: 400V-2200V
    Saída CC HV: 200 V a 600 V Garantia: 1 ano
    Tamanho: 450(C)×310(L)×360(A) Peso: 21kg

     

    Insulation Oil Dielectric Dissipation Factor Volume Resistivity Tester

    Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

     

    I. Introduction:

    Automatic Dielectric Dissipation Factor Tester is a high-precision

    instrument, which can be applied to measure dielectric loss angle and Volume Resistivity of
    insulating oil etc.
    This oil tan delta analyzer is integrated with oil cup for dielectric loss, temperature-control equipment,
    temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor,
    high resistance meter and DC high-voltage power etc.
    The most advanced heating mode of high frequency induction is applied to the heating part of this iinsulation oil dissipation factor tester, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc. AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the transformer oil volumn resistivity tester can operate correctly.
    The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and
    capacitance is not influenced by environmental temperature and dampness etc. In this way, the
    accuracy of insulation oil dielectric loss tester is guaranteed conformably after a long-time application.

     

     

    II. Specifications:

    Condition of Use -5℃-40℃ RH<80%
    Power Source AC 220V±10% Without Frequency Limit
    AC High Voltage Output 400V-2200V ±2% Every 100V 50VA
    DC High Voltage Output 200V-600V ±2%
    Temperature Control Induction Stove Maximal Power 500W
    Temperature Control Range <100℃
    Temperature Measuring Error ±0.5℃
    Control Temperature Error 0.1℃
    Control Temperature Time Room Temperature 90℃ <20min

    Measuring Range

    tgδ Without Limit

    Cx 15PF-300PF

    Rx 10M-10T

    Resolution

    tgδ 0.001%

    Cx 0.01pF

    Rx 0.01

    Precision

    delta tgδ:±(Reading*0.5%+0.020%)

    delta Cx :±(Reading*0.5%+0.5PF)

    delta Rx :±Reading * 10%

    Relative Dielectric Loss Constant Εr Calculated Automatically
    Volume Resistivity ρ Calculated Automatically
    Dimension 450(L)×310(W)×360(H)
    Net Weight 21KG
     

     

     

    Picture of Dielectric Dissipation Factor Volume Resistivity Meter

    Transformer Oil Test Set Dielectric Dissipation Factor Volume Resistivity Meter

    Contacto
    Advanced Instruments Co.,Ltd

    Pessoa de Contato: Mrs. Sandy

    Envie sua pergunta diretamente para nós (0 / 3000)