Casa ProdutosAparelho de Propagação de Chama

Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method

Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method

    • Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method
    • Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method
    • Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method
    • Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method
  • Needle Flame Test Instrument by IEC60695-2-2 Fire Hazard Testing Method

    Detalhes do produto:

    Lugar de origem: CHINA
    Marca: AI
    Certificação: ISO
    Número do modelo: NFT

    Condições de Pagamento e Envio:

    Quantidade de ordem mínima: 1 conjunto
    Preço: Negociável
    Detalhes da embalagem: Caixa de madeira compensada
    Tempo de entrega: 30 dias
    Termos de pagamento: Western Union, T/T, L/C
    Habilidade da fonte: 20 séries por mês
    contacto
    Descrição de produto detalhada
    Padrão de teste: IEC60695-2-2, IEC60695-11-5 Fonte de energia: AC220V ± 10% / 50 Hz
    Faixa de temperatura: 0--1000ºC Dimensão: L1120 * W520 * H1250mm
    Cor: Branco palavra-chave: Instrumento de ensaio de chama de agulha

    Needle Flame Test Instrument by IEC60695-2-2

     

    Introduction
    Needle Flame Test Instrument is designed according to international standards IEC60695-2-2 and IEC60695-11-5.The instrument applies for lighting, low-voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical connectors, accessories and other electrical and electronic equipment and parts, component research, production and quality control departments and insulating materials , plastic or other solid combustible materials industry to carry on small-flaming ignition experiments.
    Needle flame test instruments uses standard size (Φ0.9mm) needle burner .and burns the sample with specific gas (butane) at the angle of 45 °.It determines the ignition risk of the small-flame caused by fault conditions in the equipment by testing the sample burning situation,burningtime and burning length

     


    Technical Parameters:

     

    1 Needle burner It is made of stainless steel:the hole dia. 0.5mm ± 0.1mm, diameter≤0.9mm, length≥35mm
    2 Burner flame angle 0- 45 ° (arbitrary adjustment)
    3 The combustion gases 95% butane gas or propane gas
    4 Subplate white pine plank ( 10mm),
    Surface covered by standard silk paper
    200mm ± 5mm below the flame
    5 Temperature range 0--1000 ºC
    6 The flame temperature requirements 100 ± 2 ºC ~ 700 ºC ± 3 ºC,
    Heating rise time: 23.5 ± 1.0s;
    7 The flame height 12mm ± 1mm
    8 Ignition time 0s ~ 999.9s adjustable, generally 30s
    9 Burning time 0s ~ 999.9s, automatic recording, manual pause
    10 Test Space ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements)
    11 Temperature sensor K-type insulation-sheathed thermocouple (Φ0.5mm)
    12 Dimensions L1120 * W520 * H1250mm
    13 The diameter of exhaust Φ100mm
    14 Power supply 220V / AC, 50Hz


     