Casa ProdutosEquipamentos para Testes de Produtos Petrolíferos

ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate

ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate

    • ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate
    • ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate
  • ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate

    Detalhes do produto:

    Lugar de origem: CHINA
    Marca: AI
    Certificação: ISO
    Número do modelo: H1706

    Condições de Pagamento e Envio:

    Quantidade de ordem mínima: 1 conjunto
    Preço: Negociável
    Detalhes da embalagem: Cartão duro
    Tempo de entrega: 20 dias
    Termos de pagamento: L/C, T/T, Western Union
    Habilidade da fonte: 20 séries por mês
    contacto
    Descrição de produto detalhada
    Padrões: ASTM D5481,SH/T0703 Método de teste: Viscosímetro capilar multicelular
    Faixa de fluxo: 0~200ML/H Escala de controlo da temperatura: Temperatura ambiente ~ 150 ℃
    Mostrar: LCD Fonte de energia: AC220V ± 10%, 50Hz
    Unidade de trabalho: 1 tubo Garantia: 1 ano

     

    Apparent Viscosity Test at High Temperature and High Shear Rate

     

     

    Introduction:

    This tester is mainly used to measure apparent viscosity at high temperature and high shear rate(HTHS),the principle of which is under certain test condition at 150C,with pressure of N2(CO2),the sample flows out from capilliary viscometer,according to flowing time and pressure,we can calculate the apparent viscosity reached by apparent sheat rate of capillary viscometer.

     


    Features:

    1.This apparatus is first one in China,which is already used by many customers,

    2.Spares can be changed with imported instruments.

    3.It is supplied with special software for calculation High shear viscosity.

    4.Solvent is not needed,and it can be washed with little new sample.

    5.The apparent viscosity tester can work for 24 hours continuously.

    6.Glass capillary meets standard requirements,diameter 0.15mm,length 16mm.

    7.Different shear rate and test temperature can be set for users who make research.

    8.It is made of aluminum competely.

    9.With touch screen controlling,the operation can be done on the LCD screen directly.

    10.Test pressure is automatically caculated by software,and report of test result is exported in Excel format

     

     

    Specifications:

    Test standard ASTM D5481,SH/T0703
    Test method Multicell Capillary Viscometer
    Temperature range ambient~150C±0.1C
    Flow range 0~200ML/H
    Display LCD
    Test units 1 tube
    Display content test pressure,test time,constant time
    Result calculation Windows version advanced software
    Power supply AC220V±10%/50HZ
    Gas source

    N2 or other inactive gases

     

    Photo of Apparent Viscosity Tester at High Temperature and High Shear Rate

    ASTM D5481 Apparent Viscosity Test at High Temperature and High Shear Rate

    Contacto
    Advanced Instruments Co.,Ltd

    Pessoa de Contato: Mrs. Sandy

    Envie sua pergunta diretamente para nós (0 / 3000)