Casa ProdutosEquipamentos para Testes de Produtos Petrolíferos

UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
    • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC
  • UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    Detalhes do produto:

    Lugar de origem: CHINA
    Marca: AI
    Certificação: ISO
    Número do modelo: A91

    Condições de Pagamento e Envio:

    Quantidade de ordem mínima: 1 conjunto
    Preço: Negociável
    Detalhes da embalagem: Cartão duro
    Tempo de entrega: 20 dias
    Termos de pagamento: L/C, T/T, Western Union
    Habilidade da fonte: 20 séries por mês
    contacto
    Descrição de produto detalhada
    Padrões de teste: ASTM UOP960 Aplicativo: Medir traços de hidrocarbonetos oxigenados em fluxos de hidrocarbonetos líquidos
    Método de teste: GC Garantia: 1 ano
    Fonte de energia: AC220V ± 10% 50Hz palavra-chave: Cromatógrafo de gás UOP960

     

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

     

    Flow chart of Measuring Trace Oxygenated Hydrocarbons in Naphtha

     

    2 Configuration

    Item CAT NO. DESCRIPTION QTY
    1 G2091A A91 Plus CG 1
    2 G2011B Software 1
    3 1790M Start-up kit A(including sample injection port))  
    4 #210 FID 2
    5 #120 SISL Capillary Injection Port (0~100 psi) 1
    6 PN5.132.002 One way PCM Pressure Control Module 1
    7 #513 Three automatic valves,with valve box heating and pipeline 1
    8 #561 Six way rotor valve 2
    9 #450 Independent heating column(at the back of FID detector) 1
    10 #515 Side Valve Box 1
    11 #542 Four way liquid injection valve(1.0ul volume,75C and 1000 psi max) 1
    12 #360 Liquid injection valve back pressure damping system assembly 1
    13 ECM.7.342.001 2um stainless steel gas filter 1
    14 #610 Sample ring(0.5mL) 1
    15 PN5.150.006 Deoxidation trap 1
    16 PN5.150.004 Dewatering trap 1
    17 PN5.150.005 Dealkylation trap 1
    18 Pipeline Capillary column 1m*0.53 1
    19 Column 1 20m*530um ID*5um MXT-1,Restek Cat.No.71812 1
    20 Column 2 10m*530 u ID*10 uLowox 1
    21 Column 3 30m*0.53 1
    22 Computer Lenovo 1

     

    3.Spectrum

    UOP960 Trace Oxygenated Hydrocarbon in Liquid Hydrocarbon Streams by GC

    Contacto
    Advanced Instruments Co.,Ltd

    Pessoa de Contato: Mrs. Sandy

    Envie sua pergunta diretamente para nós (0 / 3000)