| Lugar de origem: | CHINA |
| Marca: | AI |
| Certificação: | ISO |
| Número do modelo: | KRL99 |
| Quantidade de ordem mínima: | 1 conjunto |
|---|---|
| Preço: | Negociável |
| Detalhes da embalagem: | Cartão duro |
| Tempo de entrega: | 50 dias |
| Termos de pagamento: | Western Union, T/T, L/C |
| Habilidade da fonte: | 50 conjuntos por mês |
| Padrão de teste: | CEC-L-45-A-99 | Método de teste: | Equipamento de rolamento de rolo cônico KRL |
|---|---|---|---|
| Força de teste: | 10000n | Atrito: | 200n |
| Faixa de controle de temperatura: | temperatura ambiente ~250ºC | Faixa de velocidade: | 300~1800r/min |
| Quantidade de amostra de óleo: | 10ml | Potência total: | 2.2kW |
| Dimater de esfera de aço: | 12.7 | Intervalo de tempo: | 1s~9999min |
| Dimensão: | 1300×490×1220 (milímetro) |
Summary
KRL Tapered Roller Bearing method determines viscosity and shear stability of Transmission Lubricants,
This Viscosity Shear Stability Test Equipment adopts LCD touch screen: through the screen, the oil sample temperature control, rotating shaft speed, test load, test time, shear revolution and other functions can be controlled. All key parameters and control points can be displayed at a glance, realizing a highly integrated and automated operation interface, which greatly reduces the operation difficulty of the experimenter.
I. Main technical features
1.This Viscosity Shear Stability Test Equipment adopts double floating bearing technology, non clearance guiding technology and buffer cross balancing technology are adopted to ensure the precision of real-time tracking measurement of test force and friction force;
2.The brand servo motor is used to drive the spindle, and the relevant transmission components also use imported precision bearings;
3.This Viscosity Shear Stability Test Equipment has independent embedded industrial controller, industrial metal touch screen and independent analysis module are adopted to effectively ensure the impact on the performance of the control part in case of high-speed equipment or severe vibration due to oil film rupture;
4.It can easily capture the wear spots, measure and analyze the friction surface morphology, and directly save the wear spot image;
5.The test software can establish professional test schemes according to different standards, and can also judge the Pb value according to the size of wear spots.
6.This KRL Viscosity Shear Stability Test Equipment has the function of saving and exporting data tables.
II. Main technical specifications
| Applicable standard | NB/SH/T0845-2010; CEC L-45-99 |
| Test force | 10000N |
| Below 4% of test force, indication error | ±5N |
| Above 4% of test force, indication error | ±1% |
| Friction | 200N |
| Temperature range | room temperature ~250ºC |
| Temperature control accuracy | ±3ºC |
| Speed range | 300~1800r/min |
| Speed accuracy | less than 15r/min |
| Quantity of oil sample | 10ml |
| Dimater of steel ball | φ12.7 |
| Motor power | 2.2kW |
| Timing range | 1S~9999min |
| Wear spot measurement software | Automatically capture wear spots, save and measure the average value |
| Measuring microscope magnification | 25× 200 |
| Measurng range of wear spot | 0~10mm |
| Measuring accuracy of wear spot | 0.001mm |
| Loading method of test force | Front mounted weight loading |
| Force retaining mechanism | Self balancing gapless guidance |
| The relative error of friction indication shall not be greater than | ±2% |
| Wear spot measuring microscope | Electronic measuring system |
| Dimensions | 1300×490×1220(mm) |
![]()